|
Product Details:
Payment & Shipping Terms:
|
Name: | Busbar Joint Insulation Plate | Packing: | Plywood |
---|---|---|---|
Usage: | Used For Busbar Joint | Material: | DMC |
Application: | Insulation | Certification: | ISO9001 |
Other Name: | DMC Insulation Plate | Other Name 2: | Busbar Insulation Block |
Other Name 3: | Busbar Insulation Separator | ||
High Light: | DMC Busbar Insulation Plate,Busbar Joint Insulation Plate,ISO9001 Busbar Insulation Plate |
DMC Busbar Insulation Plate For Busbar Trucking Joint
Insulation plate for busbar trucking joint
Features
Installed in joint for insulation
Material: DMC
Size and color can be customized
Product | Model | Hole Nos | Distance Between Holes |
Insulation Plate (Middle, Edge) X=122 | X=50 | 1 | |
X=65 | 1 | ||
X=85 | 1 | ||
X=90 | 1 | ||
X=105 | 1 | ||
X=120 | 1 | ||
X=140 | 1 | ||
X=150 | 2 | 80(RU) | |
X=160 | 1 | ||
X=190 | 1 | ||
X=205 | 3 | 80(RU) | |
X=210 | 2 | 105 | |
X=230 | 2 | 115 | |
X=250 | 2 | 125 | |
X=255 | 3 | 85 | |
X=310 | 2 | 169 | |
X=350 | 2 | 189 | |
X=390 | 2 | 209 | |
X=450 | 4 | 95 | |
X=490 | 4 | B=105 C=154(Middle) | |
X=658 | 6 | B=90(Middle) C=139 (Edge) | |
X=688 | 6 | B=100(Middle)C=150(Edge) | |
Insulation Plate (Middle, Edge) X=130 | X=50 | 1 | |
X=60 | 1 | ||
X=80 | 1 | ||
X=95 | 1 | ||
X=110 | 1 | ||
X=120 | 1 | ||
X=125 | 1 | ||
X=145 | 1 | ||
X=160 | 1 | ||
X=180 | 2 | 90 | |
X=190 | 2 | 85 | |
X=200 | 2 | 100 | |
X=324 | 2 | 194 | |
X=344 | 2 | 204 | |
X=354 | 2 | 209 | |
X=394 | 2 | 229 | |
X=424 | 2 | 244 | |
X=464 | 4 | B=174 C=90 | |
X=484 | 4 | B=179 C=95 | |
X=504 | 4 | B=184 C=100 | |
X=623 | 6 | B=149 C=80 | |
X=648 | 6 | B=164 C=80 |
Busbar Trunking System is the is a system of distributing electric power using copper or aluminium busbar with suitable enclosures and good amount of protection to prevent the cables from getting damaged due to foreign bodies. ... The system of cooling is much better than traditional cabling system.
Busduct joint
This joint stack design has taken into the consideration of a bigger contact surface of the conductors in order to reduce power loss and improve cooling performance.
Double headed joint bolts together with Belleville washer ensure a sufficient pressure required to secure each joint connection.
The double headed joint bolt is also designed with a specific torque value whereby the outer head of the joint bolt (which acts as
tightness indication will shear off when it reaches the limit and this will prevent over tightening of the joint section.
Contact Person: Tina
Tel: +8618115561910
Fax: 86-512-62761477-807